Component Leak Detector C15, Modular Leak Testing (2024)

Component Leak Detector C15, Modular Leak Testing (1)

The Agilent C15 Component Leak Detector is a modular leak-testing package intended for applications in which the leak detector components are integrated into the system. It incorporates Agilent's Contra-Flow vacuum design, which maximizes the protection of its components from contamination in industrial applications.

An optional color touch screen display is available for remotely showing all system status information and inputting all operating parameters.

  • Component Leak Detector

Request QuoteRelated ProductsPromotions

Request a Quote

Product Details

Features

  • Compact, easy to integrate component leak detection system that is 50% smaller than competitive systems
  • Selectable sensitivity scales and Contra-Flow™ vacuum design for fast, accurate measurements with maximum protection from contamination in industrial applications
  • Simplified interface with only two cables required, one for power, one for communications
  • Does not require mounting modules or bulky, expensive interconnecting cables
  • Comprehensive array of interface options, including serial, discrete I/O and Profinet
  • Optional color touch screen display allows access to system status information and all operating parameters.
  • Critical leak detector components are safely housed in a single enclosure protecting them from the industrial environment.
  • Shipped with a power cord
Background Suppression
  • Auto zero and auto zero < zero function
Calibration
  • Automated or manual (internal or external)
Communications Interface
  • Analog output and Serial communications are standard
  • 0-10V, log 1V/decade & 2V/decade and linear (DB-9F)
  • RS-232 isolated at 9600 baud (DB-9M)
  • Optically isolated, 5-24VDC outputs and inputs (DB-25S)
  • Profinet® I/O option (RJ45)
Display Interface
  • Optional
  • High clarity TFT
  • Color touch screen
Maximum Test Port Pressure
  • 5 Torr
  • 7 mbar
  • 667 Pa
Minimum Detectable Leak
  • 5 x 10-10atm·cm3/s, 5 x 10-10 mbar·l/s, 5 x 10-11Pa·m3/s
Operating Environment Temperature
  • 5 to 48 °C (41 to 118 °F)
Power Input
  • 24VDC ±5%, maximum current 4A (Molex connector 03-12-1036 provided)
Selectable Languages
  • Chinese
  • English
  • French
  • German
  • Japanese
  • Korean
  • Spanish
Sensitivity Ranges
  • Four working ranges covering 1 x 10-3 to 1 x 10-9 atm·cc/s
Set Points
  • Five total set points
  • Four for leak rate or pressure
  • One audio

Return to top

Videos

Literature

Brochures

Vacuum and Leak Detection Reference: Formulas, Properties, and Glossary

This reference helps users to keep important properties, formulas, and terms used in vacuum technology at their fingertips.

  • Brochures
  • English
  • 27 Oct 2022
  • 1.10 MB
  • PDF

Agilent Vacuum and Leak Detection Solutions for e-Mobility

Vacuum and leak detection solutions in advanced industrial processes for vehicle manufacturing, supporting the transition to sustainable mobility.

  • Brochures
  • English
  • 18 Aug 2022
  • 9.41 MB
  • PDF

Leak Detection of Automotive Components

Application of helium leak testing to the manufacture of automotive components, with leak rate specifications and the equivalent helium leak detection values.

  • Brochures
  • English
  • 24 Jun 2021
  • 1.37 MB
  • PDF

Agilent C15 Industrial Component Leak Detector

Brochure - C15 Industrial Component Leak Detector for easy integration into large scale production and test systems.

  • Brochures
  • English
  • 24 Mar 2020
  • 1.45 MB
  • PDF

Sustainability in the Vacuum Industry: A Guide to Agilent Vacuum and Leak Detection Green Solutions

Learn more about sustainable vacuum products and solutions in this exhaustive guide.

  • Brochures
  • English
  • 15 Sep 2023
  • 19.15 MB
  • PDF

Spanish Version: Agilent Vacuum and Leak Detection Solutions for e-Mobility

Vacuum and leak detection solutions in advanced industrial processes for vehicle manufacturing, supporting the transition to sustainable mobility.

  • Brochures
  • Spanish
  • 08 Aug 2022
  • 2.81 MB
  • PDF
Data Sheets
Software
Technical Overviews

News

What You Need to Know About Accuracy in Helium Leak Testing

This new suite of technical overviews provides a primer on accuracy, minimum detectable leak (MDL), managing background signal, and calibration for precision leak testing.

  • 21 Oct 2021

Primer - Agilent Solutions for the Lithium-Ion Battery Industry

Unclear where to begin your lithium-ion battery testing journey? Need clarity on how to address multiple testing needs? Read Agilent's introductory guide to mineral, processing, cell component, and leak testing solutions and set your lab up for success.

  • 19 Dec 2023

Support

Supplemental Information

C15 Component Leak Detector Ordering Details

User Manuals

Didn’t find what you need?

Try these resources or use Chat Now/Message Us

  • Vacuum Technical Support
  • Vacuum Community
  • Worldwide Sales and Support Contacts

Services

Whether you are just starting to use a helium leak detector or are an experienced user looking for a deeper understanding of leak detection technology and techniques, Agilent can provide customized training and support. Agilent offers training in multiple formats to fit your needs, including at your site, at an Agilent location, or online.|Agilent application engineers are skilled in both vacuum and leak detection, meaning that they can help you design a system that will meet your helium leak testing requirements. Agilent supports you before, during, and after you purchase a helium leak detector to ensure you get the right results.|Use the online chat to talk to our experts and find out more about how we can help.

Vacuum Product & Leak Detector Services

Ensure that your leak detector is in optimal operating condition. Let Agilent’s factory-trained service engineers repair and maintain your leak detector using genuine OEM parts. Our service engineers will ensure that your leak detector is running properly and has the most up-to-date software. We can service your leak detector at your location or you can ship your leak detector back to our service center.|Preventative maintenance, repair, overhaul, and leak recertification service options are available on demand. Alternatively, if you want a higher level of protection and priority, check out Agilent Service Contracts. Use the online chat for help determining the best solution for your needs.

Vacuum Product & Leak Detector Services

When you protect your Agilent helium leak detector with a service contract, you get peace of mind. Agilent factory-trained technicians will perform annual preventative maintenance procedures with the latest software upgrades and repair your leak detector using original equipment manufacture (OEM) parts as needed. What’s more, as a service contract holder you’ll get unlimited technical support via phone, chat, or email.

Vacuum Product & Leak Detector Services

Return to top

Training & Events

Vacuum Technologies Webinar Series

Join us to learn more about Vacuum Technologies and their applications!

Webinar/Training

Related Products

Promotions

Component Leak Detector C15, Modular Leak Testing (2024)
Top Articles
Latest Posts
Article information

Author: Edwin Metz

Last Updated:

Views: 6586

Rating: 4.8 / 5 (78 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Edwin Metz

Birthday: 1997-04-16

Address: 51593 Leanne Light, Kuphalmouth, DE 50012-5183

Phone: +639107620957

Job: Corporate Banking Technician

Hobby: Reading, scrapbook, role-playing games, Fishing, Fishing, Scuba diving, Beekeeping

Introduction: My name is Edwin Metz, I am a fair, energetic, helpful, brave, outstanding, nice, helpful person who loves writing and wants to share my knowledge and understanding with you.